Approved Document T explained: what it means for toilet cubicles

Short answer

Approved Document T is the Building Regulations guidance on toilet accommodation in England, in force since 1 October 2024. For new non-domestic buildings and material changes of use it asks for separate single-sex toilets for men and women, or fully enclosed universal toilets where space does not allow.

Self-contained floor-to-ceiling toilet rooms with oak-effect full-height doors
Self-contained floor-to-ceiling toilet rooms with oak-effect full-height doors Illustrative image

What the requirement says

Requirement T1 asks for reasonable provision of single-sex toilets for men and women, or universal toilets where space precludes single-sex provision. Universal toilets may also be provided in addition to single-sex toilets where space allows. A universal toilet is a fully enclosed room with its own WC, washbasin and hand-drying facilities.

Which buildings it covers

  • New buildings other than dwellings.
  • Buildings undergoing a material change of use.
  • Work that counts as a material alteration may also bring it into play; your building control body decides.
  • Exempt: dwellings, en-suites in residential rooms and care homes, schools, early years premises and cellular accommodation in custodial facilities.

The four toilet types

TypeDescription
Type AFully enclosed, self-contained ambulant universal toilet
Type BFully enclosed, self-contained universal toilet for users who may not be ambulant
Type CAmbulant single-sex toilet cubicle, not self-contained
Type DSingle-sex toilet cubicle, not self-contained

Self-contained types are built with full-height walls and a full-height door, which is where floor-to-ceiling cubicle systems come in.

Transitional provisions

The rules do not apply where a building notice, initial notice or full plans application was given before 1 October 2024 and the work was sufficiently progressed before that date or within six months of it. For new buildings, sufficiently progressed means foundation concrete or permanent piling had started.

What it means when planning cubicles

On projects where Approved Document T applies, decide early whether the layout will use separate single-sex washrooms, universal toilets, or both. Full-height cubicles change the M&E design because each compartment needs lighting, extract and fire detection. Doors should resist the passage of sound, avoid obstructing escape routes and have privacy bolts that can be opened from outside in an emergency.

Sources

Frequently asked questions

Does Approved Document T apply in Scotland and Wales?

No. Approved Document T is guidance for England. Scotland and Wales have their own building standards.

Does it apply to a washroom refurbishment?

It applies to new non-domestic buildings and material changes of use. Whether a refurbishment counts as a material alteration that brings it into play is a decision for your building control body, and we check this at design stage.

Planning new toilet cubicles or a washroom refit?

Get a guide price in under a minute, then a free survey and a fixed written quote.